English
...
Load Management
Charging Station Configuration...
Zaptec Pro and Home
as the communication is from cloud to cloud, an internet connection is required on zaptec portal go to tab “installations” and the “>” symbol for the correct installation copy installation id and enter it in the clemap load management ev charger setup after selecting “zaptec” as charger type note make sure to enter the circuit current limit and not the single charging station limit in the clemap load management web interface in this example the circuit is secured with 63 a the main current limit is set to 125 a in menu «settings», «power management» enter maximum circuit breaker values (7 ), select manual power control (8 ) and enter total available current per phase, clemap load management will then overwrite this value (9 ) clemap load management will dynamically manage the available current in the background configure access data finally add the cloud provider access data docid\ vnvvizubuhwom nl4tbzd so that the clemap load management device can control the zaptec charging station via the zaptec cloud