Firewall Ports and Addresses
Which ports does CLEMAP Load Management communicate through?
The Edge device establishes connections via the following ports:
Adress/Service | Port | Description | Direction | Required/Optional |
|---|---|---|---|---|
dns | UDP/TCP 53 | Translates human-friendly domain names into IP addresses. | outbound | Required |
mqtt.cloud.clemap.com | TCP 8883 TCP 3032 | Standard communication with the main CLEMAP MQTT broker. Communication is encrypted: MQTT over SSL. | outbound | Required |
bitbucket.org | TCP 22 | Firmware updates are downloaded from this address. Communication is encrypted via SSH. | outbound | Required |
*.ntp.org | UDP 123 | Time server used to synchronize the time on CLEMAP devices. NTP is essential for accurate and consistent timekeeping across the network, as it allows CLEMAP devices to use a common time reference. | outbound | Required |
log.cloud.clemap.com | TCP 3100 | Used to send device logs to the CLEMAP cloud logging service. | outbound | Required |
s2.cloud.clemap.com | TCP 3024 TCP 3080 | Remote access to devices via SSH for support. | outbound | Required |
b2.cloud.clemap.com | TCP 8883 | Communication with the CLEMAP monitoring MQTT broker. Communication is encrypted: MQTT over SSL. | outbound | Required |
static-edge-device-ressources-clap.s3.eu-central-1.amazonaws.com | TCP 443 | Used to download CLEMAP device resources from AWS S3, including the Teleport installation archive. | outbound | Required |
lokal | TCP 7000 | Used for communication between cascaded parent and child CLEMAP Load Management systems. | Nur im lokalen Netzwerk | Optional |
lokal | TCP 8050 | Used by charging stations to connect via OCPP. | Nur im lokalen Netzwerk | Optional |
lokal | TCP 7050 | Used by charging stations to connect via OCPP. | Nur im lokalen Netzwerk | Optional |
https://api.zaptec.com | TCP 443 | Control of Zaptec charging stations via Zaptec Cloud for CLEMAP Load Management. | outbound | Optional |
https://api.easee.com | TCP 443 | Control of Easee charging stations via Easee Cloud for CLEMAP Load Management. | outbound | Optional |
https://api.smart-me.com | TCP 443 | Control of Pico Smart-me charging stations via the smart-me Cloud for CLEMAP Load Management. | outbound | Optional |