Schrack EMCIONP2P0
For detailed instructions, refer to the operating and configuration manuals:
The following guide is intended as a quickstart.
Hardware Setup:
The image below briefly shows how to mount the Schrack charging station.

The Schrack charging station can be operated with one phase or all three phases. It is important that the power cables are properly arranged and connected, as shown in the image:

The following image shows where the Ethernet cable must be connected for communication with the Clemap sensor.

Software Configuration of the Charging Station:
Use an IP scanning tool (e.g., Advanced IP Scanner) to determine the IP address of the charging station in the local network. Then enter the detected IP address in a browser to access the station’s web interface. Log in using the username "operator" and the password "Schrack1230!".

The dashboard displays current information about the charging stations, including general notifications, GSM/network connection status, errors, etc.

By default, the network is configured to DHCP.
Under LASTMANAGEMENT > Modbus Interface, configure the following parameters:
- Modbus TCP Server for energy management systems: On
- Modbus TCP Server Register Set: Open Modbus Charge Control Interface (OMCCI)

To use the local RFID whitelist, the following basic settings are required:
- Free charging set to “Off”, i.e., deactivated
- Local whitelist activated set to “On”, i.e., activated


Click on “Add entry” in the “Whitelists” submenu.

A new window will then appear, as shown below.

Now hold the RFID card to be registered against the reader on the charging station. The RFID tag will automatically be read by the station.

Then click on “Add entry”. The RFID tag is now stored, and another tag can be added. Each additional RFID card is registered using the same process.