English
...
Load Management
Charging Station Configuration...
Hager Witty OCPP
1\) connect the station and make sure that you have a ethernet connection with it it is important that it is in the same network 2\) do an ip scan, and identify the hager station ip address also identify the clemap sensor ip address 3\) go into the local web ui of the station by entering the hager station ip address as url in your browser 4\) enter with the credentials of the station 5\) at the ocpp menu for a normal connection , enter the clemap ocpp server url ws\ //\[sensor ip address] 7050/ for a proxy connection , you need to access a different port, so the url is ws\ //\[sensor ip address] 8050/ for a proxy connection with ecarup , please first make a connection directly with the ecarup backend and restart after the charger appeared in the ecarup backend, change the ocpp url in the station to ours (ws\ //\[sensor ip address] 8050 /) and restart the charger else your charger might not appear in their backend there is an issue with the bootnotification we are working to solve thank you! ecarup configuration instructions https //ecarupwiki smart me com/ocpp ladestationen/hager https //ecarupwiki smart me com/ocpp ladestationen/hager 6\) now at the local interface of the sensor happy charging!