English
...
Load Management
Charging Station Configuration...
Keba P30
keba p30 a series enable input dsw1 1 to on connect c lm outa+ to keba x1/left, outa to x1/right set outputs on c lm local webinterface set outputs keba p30 x series and c series dip switches dsw1 3 to on (modbus communication) dsw2 5 off (communication in a proprietary charging network) changes to the dip switch settings only become effective after a restart of the charging station! the following requirements have to be met in order to use the modbus tcp functionality kecontact p30 c series with firmware version 3 10 16 or higher , or kecontact p30 x series with software version 1 11 or higher the charging station has to be connected (via lan cable) to the same network as the application specific setting for the x series in the local web interface of the charging station api access settings > api status > off finally, add the charging station to the list of charging stations connected to clemap load management ip adress local ip address of the charging station for example 192 168 1 103 port 502 example configuration of a keba p30 c series