Français
...
Load Management
Configurations des Stations de...
General OCPP (englisch)
1\) you need to have access to the stations configuration some stations work via local web interface (ip address of the station on the browser) and others you have to call support so they configure it for you 2\) on the configuration panel you have to add the clemap's device ocpp url for a normal connection , enter the clemap ocpp server url ws\ //\[sensor ip address] 7050 / for a proxy connection , you need to access a different port, so the url is ws\ //\[sensor ip address] 8050 / for the sensor ip address you have to do a scan in the local network and find it 3 1) for a proxy connection , you have to add the identifier and the additional backend url at the chargers configuration in floem for a proxy connection with ecarup , please first make a connection directly with the ecarup backend and restart after the charger appeared in the ecarup backend, change the ocpp url in the station to ours (ws\ //\[sensor ip address] 8050 /) and restart the charger else your charger might not appear in their backend there is an issue with the bootnotification we are working to solve thank you! 3 2) for a normal connection , you just add the identifier the identifier is important, if it does not match to the identifier provided in the chargers configuration, the connection will be rejected 4\) here one example of a client of us, who uses a proxy with ecarup happy charging!