As the communication is from cloud to cloud, an internet connection is required.

Add [email protected]as Mantainer in Zaptec platform (https://portal.zaptec.com)

On Zaptec Portal go to tab “Installations” and the “>” symbol for the correct installation.

Document image


Go to Tab “Permission” and select “Give permission”.

Document image


Add user [email protected] as Maintainer/Service

Document image


Copy installation ID and enter it in the CLEMAP Load Management EV-Charger Setup after selecting “Zaptec” as Charger Type.

Document image


Note: Make sure to enter the circuit current limit and not the single charging station limit in the CLEMAP Load Management web interface. In this example the circuit is secured with 63 A the main current limit is set to 125 A.

Document image


In menu «Settings», «Power management»: enter maximum circuit breaker values (7.), select manual power control (8.) and enter total available current per phase, CLEMAP Load Management will then overwrite this value (9.).

CLEMAP Load Management will dynamically manage the available current in the background.