title: Step 5 : Integration of ripple control signal from power supply company
slug: help-center/step-5-integration-of-ripple-control-signal-from-power-supply-company
docTags: 
createdAt: 2023-09-20T13:19:06.110Z
---

*CLEMAP Load Management* supports external control signals, e.g. from the utility company.

·      via digital input (24VDC)

·      via the cloud via RestAPI interface

Supported modes are Normal, Reduced and Locked.



::Image[]{src="https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/WQW6vg8-Zb-qJIK3g4IfC_clemap-rundsteuer-empfanger-fnn-steuerboxen.png" size="36" width="208" height="221" position="center" caption="Figure 15: Local connection of the ripple control signal" darkWidth="208" darkHeight="221" showCaption="true"}



# Configuration&#x20;

The remote control signal is configured according to the image in the local user interface under *Device Config --> External Input Mapping* of the CLEMAP load management system.

![Device Configuration and External Input Mapping](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/yKmri5iyfrBp8UP2mTcrm_sperrsignal1.png "Device Configuration and External Input Mapping")

**Remote control signal configured as normally closed** (default configuration in the CLEMAP Load Management system): The normal state is open, meaning that 0 VDC are present at the input. Once a signal comes from the energy provider, the relay closes, and 24 VDC are then present at the input.

![Normally closed configuration](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/83WlVpUMqJKSH9_0bm0uD_sperrsignaldefault.png "Normally closed configuration")

**Remote control signal configured as normally open**: The normal state is open, meaning that 24 VDC are present at the input. Once a signal comes from the energy provider, the relay opens, and 0 VDC are then present at the input.

![Normally open configuration](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/bWddI7T54JkyhiX_5wj8j_sperrsignalopposite.png "Normally open configuration")

**Available settings**

| Setting                      | Description                                                                                            |
| ---------------------------- | ------------------------------------------------------------------------------------------------------ |
| Normal                       | Normal operation without any special restrictions                                                      |
| Disabled                     | The charging stations are blocked or disabled                                                          |
| Limited to minimum           | The charging stations deliver the minimum permitted power                                              |
| Relative reduced limit (50%) | The charging stations deliver no more than 50% of their individual allocation                          |
| Reduced main limit (10–90%)  | The load management’s main current limit is reduced to the selected percentage of the configured limit |

# Display of Active Control Signal

Once the time tariff control signal is active and recognized by CLEMAP Load Management, it is displayed on the CLEMAP Floem platform.

![Display of active control signal ](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/IP_afjv9vpTFjwhO-phwX_image.png "Display of active control signal ")