title: Siemens Sicharge
slug: help-center/ksAA-siemens-sicharge
docTags: 
createdAt: 2024-02-18T19:57:58.980Z
---

**1)** Make sure that the EVSEs is in the same local are network as the CLEMAP device.

**2)** Scan the **IP Address** of the EVSE.

**3)** Access the local interface of the charging station by entering the IP address.

**4)** Enable "Open ports through VLan on WAN port to the PLC", and enter IP address
10.20.37.x to act as the IP address of the Modbus server for the ELMS communication

**5)** Ensure that the IP address of the CLEMAP controller is in the same range as the siemens (10.20.37.y in this example).

**6)** Press the CONFIGURE VLAN button to save the configuration on the router
permanently.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/DRr2wINnuWuOzBm-DeUKC_image.png)

**7)&#x20;**&#x52;estart the loading station.

**8)** Enter the **IP Address** and the **port&#x20;**(400 in this case) into the CLEMAP web UI.

Happy charging!