title: Keba P30
slug: help-center/keba-p30
docTags: 
createdAt: 2023-09-08T17:20:53.137Z
---

:::hint{type="warning"}
For the P40, the settings must be made in the corresponding app and not in the browser.

The app can also be used for the P30.

**Android:** Google Play Store – KEBA eMobility App

**iOS:** App Store – KEBA eMobility App
:::

### KEBA P30 / a-series

- Enable Input DSW1.1 to ON.
- Connect C-LM OutA+ to KEBA X1/left, OutA- to X1/right.
- Set Outputs on C-LM local webinterface Set Outputs.




::Image[]{src="https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/LKAcP9HeUU7mO5E-zt9eo_image.png" size="42" width="415" height="213" position="center" darkWidth="415" darkHeight="213" showCaption="false"}

::Image[]{src="https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/iM5crgkAlfdffJX_P8w81_image.png" size="34" width="251" height="278" position="center" darkWidth="251" darkHeight="278" showCaption="false"}

::Image[]{src="https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/R61VwCLE4muk1m1b4Yun8_image.png" size="60" width="467" height="728" position="center" darkWidth="467" darkHeight="728" showCaption="false"}

### KEBA P30 x-series and c-series

- DIP switches:
  - DSW1.3 to ON (Modbus communication)
  - DSW2.5 OFF (Communication in a proprietary charging network)
- Changes to the DIP switch settings only become effective after a restart of the charging station!

::::hint{type="danger"}
The following requirements have to be met in order to use the Modbus TCP functionality:

:::Paragraph{listStyleType="disc" indent="2"}
**KeContact P30 c-series** with firmware version **3.10.16 or higher**, or **KeContact P30 x-series** with software version **1.11 or higher.**
:::
::::

&#x20;

:::Paragraph{listStyleType="disc" indent="2"}
The charging station has to be connected (via LAN cable) to the same network as the application.
:::

::Image[]{src="https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/cLF1SlCDDvS830GGntXb7_image.png" size="62" width="598" height="562" position="center" darkWidth="598" darkHeight="562" showCaption="false"}

- Specific setting for the X-series in the local web interface of the charging station:
  - API Access Settings --> API Status --> OFF

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/HZUkFq-gb6bcaZG5Xo6Of_image.png)

- Finally, add the charging station to the list of charging stations connected to CLEMAP Load Management.

| &#x20;        |                                                                      |
| ------------- | -------------------------------------------------------------------- |
| **IP Adress** | Local IP address of the charging station. For example: 192.168.1.103 |
| **Port**      | 502                                                                  |

![Example configuration of a KEBA P30 c-series.](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/u_HEbBd3mm8YYZ0YpFhjt_image.png "Example configuration of a KEBA P30 c-series.")