title: Weidmüller AC SMART
slug: help-center/fTD8-weidmuller-ac-smart
docTags: 
createdAt: 2023-09-08T17:59:58.266Z
---

:::hint{type="danger"}
Before integration into Clemap, we recommend loading firmware 01.08.01 or higher onto the wallbox
:::

:::hint{type="info"}
In addition to the IP address, it is now also possible to reach the wallbox via a domain in the local network. The domain follows the scheme: **serialnumber.local**
If a customer can no longer find the IP of the charging station, he can enter the serial number followed by .local in the browser.
For example, **AX3F22EM1100004.local&#x20;**&#x61;nd after logging in he will be taken directly to the charging station and can read the IP address under Network.
:::

- Activate DHCP in the webui. To login use credentials in the guide.



![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/sfepGlig6y62uA1bQUXVv_image.png)

- IMPORTANT: Activate Box as Satellite.
- Make sure the CLEMAP lm is connected so it can write the timeout register every minute, else it will go into error.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/qNUr3laYC7_dbi0aNhmGO_image.png)

Modbus TCP Settings

- Please make sure it is on wi fi or LAN, depending on your config.


![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/RjtWEeHd6EZ2K5kBGzk0S_image.png)

- Please make sure that Charge settings: Availability is on „Available“.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/XedwwbZrLA8oPC2GZc54B_image.png)

- It is recommended to disable ocpp if there is no ocpp connection to avoid errors.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/BOWLzrc3e5NwHHFbbNPYG_image.png)