Load Management
Charging Station Configuration...

Keba P30

KEBA P30 a-series

  • Enable Input DSW1.1 to ON.
  • Connect C-LM OutA+ to KEBA X1/left, OutA- to X1/right.
  • Set Outputs on C-LM local webinterface Set Outputs.
Document image

Document image

Document image


KEBA P30 x-series and c-series

  • DIP switches:
    • DSW1.3 to ON (Modbus communication)
    • DSW2.5 OFF (Communication in a proprietary charging network)
  • Changes to the DIP switch settings only become effective after a restart of the charging station!
  • The following requirements have to be met in order to use the Modbus TCP functionality:
    • KeContact P30 c-series with firmware version 3.10.16 or higher, or KeContact P30 x-series with software version 1.11 or higher.
    • The charging station has to be connected (via LAN cable) to the same network as the application.
Document image

  • Specific setting for the X-series in the local web interface of the charging station:
    • API Access Settings --> API Status --> OFF
Document image

  • Finally, add the charging station to the list of charging stations connected to CLEMAP Load Management.





IP Adress

Local IP address of the charging station. For example: 192.168.1.103

Port

502

Example configuration of a KEBA P30 c-series.