**1)** Enter webUI using the charging station’s IP Address or IP\_ADDR:25000.

**2)&#x20;**&#x59;ou can change language clicking the flag in the top right corner.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/mmstKdLRnSj39pDl8KxaE_image.png)

**3)** At the LAN tab you can set a fixed IP Address for the station.


![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/qpnh0xO6EpnBl-agxMjs2_image.png)

**4)** Leave DHCP switched on at the charging station and save a fixed IP address in the router. You can also choose a static one to make sure it does not change in the future.


**5)&#x20;**&#x46;or certain versions you will have to activate the **Modbus TCP Server** and set the Register Address Set on MENNEKES.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/kgTFHZy2noE584NLlOx_O_image.png)

**6)&#x20;**&#x54;he setting "Dynamic Load Management - DLM Master/Slave" must be set to "DLM Master (With internal DLM Slave)".


![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/jebevTJvPUtZxHkr7D-C6_image.png)

**7)&#x20;**&#x50;lease check that in the installation tab, that the **Installation Current Limit** is set to your needs.


![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/Gc4IGv1iMlSO9ifSqogyf_image.png)

**8)** Also please check that in the load management tab, the **Operator Current** Limit is set to your needs.


![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/v8HrMD_FS7r0lCQ3bfx4x_image.png)

Happy charging!