title: EVTEC Modbus 1.0
slug: help-center/7RN--evtec-modbus-10
docTags: 
createdAt: 2023-10-23T10:27:08.486Z
---

:::hint{type="info"}
Please read the [EVTEC](docId:6DHRjiBHTpHrZSYPbT0_-)  page completely before starting the configuration.
:::

### 1. Basic principle

For the integration of an EVTEC charging station via Modbus 1.0, each charging connector (plug) must be created as a separate charging station.

Only in this way can the load management function correctly between the individual charging connectors.

**Important:**

- The same IP address is used for all charging connectors.
- Port: 5020

### 2. Selecting the correct plugs

Several plug options are available during configuration.

![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/zeostzuvbIJQpRBkrq3o-_evtec-plug-legacy.png)

⚠ **Important:&#x20;**&#x54;he variants marked with “(Legacy)” must always be used.

### 3. Technical configuration of the plugs

:::hint{type="info"}
If you have questions regarding the configuration of the plugs, please contact the EVTEC service team: service\@evtec.ch / +41 41 322 23 86
:::

- Charging connector 1: always DC
- Charging connector 2: AC or DC (depending on configuration)
- Charging connector 3: always DC

A maximum of 3 charging connectors are available.

::::Tabs
:::Tab{title="Charging connector 1"}
![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/08BzHyl958yXYg59KjAHl_evtec-mb1-ladestecker1.png)
:::

:::Tab{title="Charging connector 2"}
![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/lIvKhaAC3GHp0JG1hY5w9_evtec-mb1-ladestecker2.png)
:::

:::Tab{title="Charging connector 3"}
![](https://api.archbee.com/api/optimize/N5BtsfQVOxPnQzfUQkalm/KufNOhd5v3j6Kl_IG9ysy_evtec-mb1-ladestecker3.png)
:::
::::

### 4. Configuration for stations with 2 charging connectors

If the charging station has only 2 charging connectors:

- Use charging connector 1 and charging connector 2
- Charging connector 3 must not be selected, as it will not respond.

### 5. Notes

With the Legacy model, a minimum current of 6A may lead to insufficient power consumption.

**Recommandation** : Set the minimum current to 20A.